ISBN: 9798174196315 - anesthesia equipment reference 2026-2027: a clinical textbook covering gas delivery systems, breathing circuits, and patient monitoring for perioperative technologists (1 Ergebnisse)

ISBN: 
Mit der Detailsuche verfeinern

Optimieren Sie Ihre Suche

  • Bücher (1)

  • Neu (1)

bis

Benutzerdefinierte Preisspanne (EUR)

bis

  • Sprache: Englisch

    Verlag: Amazon Digital Services LLC - Kdp Sep 2026, 2026

    9798174196315

    • Softcover

    Anbieter: AHA-BUCH GmbH, Einbeck, DeutschlandAHA-BUCH GmbH

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 154,34

    EUR 35,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 2 verfügbar

    Taschenbuch. Zustand: Neu. Neuware - Trace Any Equipment Fault Back to Its Source Before It Reaches the Patient This reference explains the machinery that stands between a clinician's intention and a patient's breath: medical gas supply, the workstation and its pressure zones, vaporizers, breathing systems and absorbents, ventilators, airway hardware, gas and physiologic monitoring, infusion technology, and the safety architecture around all of it. Thirty chapters build each device from its physics to its bedside behavior, then show precisely how it fails and what that failure looks like on the display in front of you. It is written for anesthesia technologists, residents, and nurse anesthetists expected to explain why the delivery system is misbehaving. Every chapter carries The Fault Trace System: a five-part block that starts with the signal you actually see, traces it back through the physical system, names the fault, separates the look-alikes, and ends in one decisive action. Inside this edition you will find: - Gas physics applied to real hardware, including why a nitrous oxide gauge holds steady while the cylinder empties and why oxygen behaves differently- Pipeline, manifold, and cylinder faults, so a crossover or supply failure is recognized while every pressure alarm on the machine stays silent- Vaporizer physics, misfilling, tipping, and the pumping effect, so an agent monitor that disagrees with the dial tells you which direction of error you face- Circle systems, unidirectional valves, and absorbent chemistry, separating exhausted absorbent from valve incompetence in two observations- Ventilator drive mechanisms, modes, waveforms, and loops, using the peak-to-plateau difference to route a pressure alarm toward the apparatus or the chest- Airway, monitoring, infusion, and ultrasound equipment, covering cuff pressure, sampling artifacts, damping, dead space, and the failures each produces>Open it at the signal in front of you, follow the trace, and know what to do next.…