9786139460748 - method development & validation of diclofenac sodium and pantoprazole: simultaneous estimation in bulk dosage form von chaki, imran; acharya, hardik; pujara, naisarg (3 Ergebnisse)

- Softcover
Anbieter: Revaluation Books, Exeter, Vereinigtes KönigreichRevaluation Books
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 98,44
EUR 11,61 VersandVersand von Vereinigtes Königreich nach USAAnzahl: 1 verfügbar
Paperback. Zustand: Brand New. 120 pages. 8.66x5.87x0.39 inches. In Stock.

- Softcover
Anbieter: preigu, Osnabrück, Deutschlandpreigu
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 47,20
EUR 70,00 VersandVersand von Deutschland nach USAAnzahl: 5 verfügbar
Taschenbuch. Zustand: Neu. Method Development & Validation of Diclofenac Sodium and Pantoprazole | Simultaneous Estimation in Bulk Dosage Form | Imran Chaki (u. a.) | Taschenbuch | 120 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786139460748 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher… Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Softcover
Anbieter: Buchpark, Trebbin, DeutschlandBuchpark
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Gebraucht
EUR 25,73
EUR 105,00 VersandVersand von Deutschland nach USAAnzahl: 3 verfügbar
Zustand: Hervorragend. Zustand: Hervorragend | Sprache: Englisch | Produktart: Bücher | The present work describes various methods for the simultaneous estimation of Diclofenac sodium (DICLO) and Pantoprazole (PANTO) in combined Capsule dosage form. A simple, accurate and reproducible RP-HPLC method have been developed and valid…ated for the simultaneous estimation of Diclofenac sodium and Pantoprazole in their marketed formulation. The RP-HPLC methods were validated by Stastically. The retention times of Diclofenac sodium and Pantoprazole were found to be 3.33 ± 0.10 min and 6.66 ± 0.10 min, respectively. Linearity was evaluated over the concentration range of 18.75-56.25 µg/ml for DICLO and 5-15 µg/ml for PANTO by RP-HPLC method. The correlation coefficient and accuracy of both the methods were found to be within the range. The % RSD of precision was found to be NMT 2.0 % for HPLC method. The proposed methods were found to be robust when slight but deliberate changes were made in analytical conditions. Simple, accurate and reproducible RP-HPLC method were developed and validated for the simultaneous estimation of Diclofenac sodium and Pantoprazole in their marketed formulation. The proposed methods can be applied for the routine analysis in quality control laboratory.