Switching in Electrical Transmission and Distribution Systems
Sprache: Englisch
Verlag: John Wiley & Sons Inc, 2014
- Hardcover
- Neu

Anbieter: Revaluation Books, Exeter, Vereinigtes KönigreichRevaluation Books
AbeBooks-Verkäufer/-in seit 6. Januar 2003
Zustand: Neu
EUR 185,85
Anzahl: 2 verfügbar
In den WarenkorbArtikelbeschreibung vom Verkäufer
Bestandsnummer des Verkäufers x-1118381351
- Titel
- Switching in Electrical Transmission and Distribution Systems
- Autor
- Smeets, Rene/ Van Der Sluis, Lou/ Kapetanovic, Mirsad/ Peelo, David F./ Janssen, Anton
- Verlag
- John Wiley & Sons Inc
- Veröffentlichungsjahr
- 2014
- Zustand
- Brand New
- Einband
- Hardcover
- Sprache
- Englisch
- ISBN-10
- 1118381351
- ISBN-13
- 9781118381359
- Artikelgewicht
- 0,82 Kilogramm
Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage.
The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests.
Other highlights include: up to date commentary on new developments in transmission and distribution technology such as ultra-high voltage systems, vacuum switchgear for high-voltage, generator circuit-breakers, distributed generation, DC-interruption, aspects of cable systems, disconnector switching, very fast transients, and circuit-breaker reliability studies.
Key features:
- Summarises the issues and technological solutions associated with the switching of currents in transmission and distribution systems.
- Introduces and explains recent developments such as vacuum switchgear for transmission systems, SF6 environmental consequences and alternatives, and circuit-breaker testing.
- Provides practical guidance on how to deal with unacceptable switching transients.
- Details the worldwide IEC (International Electrotechnical Commission) standards on switching equipment, illustrating current circuit-breaker applications.
- Features many figures and tables originating from full-power tests and established training courses, or from measurements in real networks.
- Focuses on practical and application issues relevant to practicing engineers.
- Essential reading for electrical engineers, utility engineers, power system application engineers, consultants and power systems asset managers, postgraduates and final year power system undergraduates.
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Über die Autorin bzw. den Autor
René Smeets has for more than 30 years been involved in switching with switchgear ranging from 10–1200 kV. For the last 19 years he has worked at DNV GL (former KEMA) high-power laboratory in the Netherlands. Alongside this he is active in various positions in CIGRE: as convener and member of working groups dealing with switching equipment and testing. He is also a convener of IEC standardization teams with respect to high-voltage switchgear. He is a Fellow of IEEE. Amongst his scientific activities, he is currently chairman of the “Current Zero Club”, an informal group of specialists dealing with current interruption phenomena. He holds a Ph.D. and was appointed as a part-time professor at Eindhoven University in 2001 and adjunct-professor at Xi’an Jiaotong University in 2013. He has been a guest-editor of IEEE Journals and has published numerous papers on switching and testing. He has given courses on switching and switchgear worldwide.
Lou van der Sluis obtained his M.Sc. in electrical engineering from the Delft University of Technology. He joined the KEMA High Power Laboratory in 1977 as a test engineer and was involved in the development of a data acquisition system, computer calculations of test circuits and the digital analysis of test data. Since 1992 he has been employed as a full-time professor at the Delft University of Technology in the Power Systems Department. He is a senior member of IEEE and past convener of CC 03 of CIGRE/CIRED studying the transient recovery voltages in medium and high voltage networks. He is currently a member of CIGRE WG A3.24 on internal arc testing and co-convener of CIGRE WG C4.502 studying the interaction between high-voltage overhead lines and underground cables. He is a member of the advisory board of CIGRE SC A3.
Mirsad Kapetanoviæ received the M.Sc. degree in endurance of high-voltage circuit breakers in 1993, and the Ph.D. degree for discovery of Algebra of fractal vector (Bosnian algebra) in 1997 from the Sarajevo University, Bosnia and Herzegovina. He has been with the Energoinvest Electric Power Institute (IRCE), Sarajevo, since 1977. In 1982, he became Head of the high voltage circuit-breakers design department at IRCE. In 1997, he was appointed part-time professor at the Faculty of Electrical Engineering, University of Sarajevo. Currently, he is Professor at the faculty and part-time R&D Manager of EnergoBos Company from Sarajevo. Dr. Kapetanovic is a Member of IEEE, Distinguished Member of CIGRE, regular member of CIGRE Study Commitee SC A3 (High Voltage Equipment), 2002–2008; regular member of SC 13 (Switching Equipment), 1996–2002; and, as of 1990, member of the CIGRE Working Group 13.01 (Practical Application of Arc Physics in Circuit Breakers).
David Peelo was born in 1943 in Dublin, Ireland. After completing high school, he studied electrical engineering at University College Dublin and graduated cum laude in 1965. His first employment was at the ASEA High Voltage Laboratory in Ludvika, Sweden. In 1973 he joined BC Hydro in Vancouver, British Columbia, Canada, eventually becoming a switchgear and switching specialist. He took early retirement in 2001 to pursue a new career as an independent consultant and to undertake postgraduate work as represented by this thesis. He obtained a Ph.D. degree in switching with HV air-break disconnectors in 2004. He is active in CIGRE, IEC and IEEE committees and working groups and has authored or co-authored over 40 technical papers.
Anton Janssen served 35 years in management functions within the electric transmission and electricity/gas distribution industry, including management responsibility for KEMA High Power Laboratory. He is active in national and international organizations dealing with technical, managerial and strategic network issues. He was convener of a number of CIGRE working groups and was special reporter at many CIGRE SC 13/A3 sessions and symposia. Mr Janssen has special interest in the fields of electric transients, in protection and system stability issues, in asset- and life-management issues, in network development and planning, in optimizing the combination of various energy carriers (such as gas, electricity and heat), in the co-operation between utilities and authorities, in optimizing the network and substation topology, in incorporating the volatile sustainable sources of power (electricity, gas and a combination of both) and in coaching Ph.D. students.
„Über diesen Titel“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Revaluation Books
Exeter, Vereinigtes Königreich
AbeBooks-Verkäufer/-in seit 6. Januar 2003
Versandkosten von Vereinigtes Königreich nach USA
| Artikel | 7 bis 14 Werktage | 2 bis 3 Werktage |
|---|---|---|
| Erster Artikel | EUR 14,55 | EUR 29,10 |
Zahlungsarten
Unternehmensdaten der Verkäuferin bzw. des Verkäufers
Edward Bowditch Ltd
Exstowe, Exton
Exeter, Vereinigtes Königreich EX3 0PP
Verkaufsbedingungen
Legal entity name: Edward Bowditch Ltd
Legal entity form: Limited company
Business correspondence address: Exstowe, Exton, Exeter, EX3 0PP
Company registration number: 04916632
VAT registration: GB834241546
Authorised representative: Mr. E. Bowditch
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an Revaluation Books, Hounslow, United Kingdom, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Orders usually dispatched within two working days.