Packed Column Sfc (rsc Chromatography Monographs)
Sprache: Englisch
Verlag: Royal Society of Chemistry, 1995
- Hardcover
- Neu

Anbieter: Romtrade Corp., STERLING HEIGHTS, MI, USARomtrade Corp.
AbeBooks-Verkäufer/-in seit 17. April 2013
Zustand: Neu
EUR 65,25
Anzahl: 1 verfügbar
In den WarenkorbArtikelbeschreibung vom Verkäufer
This is a Brand-new US Edition. This Item may be shipped from US or any other country as we have multiple locations worldwide.
Bestandsnummer des Verkäufers ABBB-142221
- Titel
- Packed Column Sfc (rsc Chromatography Monographs)
- Autor
- Berger, T A
- Verlag
- Royal Society of Chemistry
- Veröffentlichungsjahr
- 1995
- Zustand
- New
- Einband
- Hardcover
- Sprache
- Englisch
- ISBN-10
- 0854045007
- ISBN-13
- 9780854045006
Packed Column SFC is the third title to be published in this series and has been produced as a result of the dramatic re-emergence, in the last three years, of packed column instrumentation. This has led to a redefinition of the technique and an urgent need for a practical guide that deals with its subtleties. This book fulfils that need and deals exclusively with packed column SFC. It places the emphasis on understanding the underlying chemistry in order to perform rapid, systematic optimizations and provides many practical tips to help the new user avoid problems unique to SFC. It also proposes a detailed scheme for method development and provides lists of prioritized guidelines. The book clears up some of the confusion that surrounds the analytical use of supercritical fluids and assists the user in understanding the power and utility of this technique. Detailed chapters cover the most promising new application areas for packed column SFC, which are often overlooked in the mainstream chromatography literature. Like the other books in this popular series, Packed Column SFC will prove an invaluable guide and is essential reading for graduates, postgraduates and researchers with interests in pharmaceuticals, agricultural chemistry, small polar drug molecules, chiral analysis, environmental chemistry, and chromatography/instrumentation.
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Auszug. © Genehmigter Nachdruck. Alle Rechte vorbehalten.
Packed Column SFC
By T. A. BergerThe Royal Society of Chemistry
All rights reserved.
Contents
Chapter 1 Putting Packed Column Supercritical Fluid Chromatography into Perspective, 1,
Chapter 2 Practical Aspects of SFC Hardware, 22,
Chapter 3 Physical Chemistry of Mobile Phases Used in Packed Column SFC, 43,
Chapter 4 Physical Chemistry of the Stationary Phase, 72,
Chapter 5 The Effect of Instrumental Parameters on Retention, Selectivity, and Efficiency, 97,
Chapter 6 Concepts That Simplify Phase Selection, 113,
Chapter 7 Systematic Method Development, 133,
Chapter 8 Pharmaceutical Analysis by Packed Column SFC, 151,
Chapter 9 Chiral Analysis of Drugs, 176,
Chapter 10 Separation of Agricultural Chemicals by Packed Column SFC, 192,
Chapter 11 SFC and the Petroleum Industry, 212,
Chapter 12 Miscellaneous Applications of Packed Column SFC, 227,
Subject Index, 245,
CHAPTER 1
Putting Packed Column Supercritical Fluid Chromatography into Perspective
Introduction
What Is Packed Column SFC?
Packed column supercritical fluid chromatography (SFC or pSFC) is an analysis technique similar to liquid chromatography (LC) that uses supercritical fluids (SFs), instead of liquids, as the mobile phase (MP) (supercritical fluids are defined in the next section). The MP solvates the solutes. The stationary phase (SP) consists of a bed of very small particles packed in a tube capable of withstanding high pressures. Some SPs are the surfaces of uncoated particles. Some are organic films bonded to the surface of the particles. Solutes are separated by differential attraction to the SP.
Compared with LC, packed column SFC is faster, more efficient, has a wider range of selectivity, and detection options, and produces less toxic waste. Not surprisingly, the fields most likely to be affected by packed column SFC in the future are traditional LC application areas. In particular, pharmaceutical and agricultural chemical development will derive significant benefits. Chiral separations will likely be a major application area for packed column SFC. This list is likely to surprise many readers since the application areas most often associated with capillary SFC have involved less polar but perhaps more complex solute mixtures such as homologous series, of surfactants, polymers, and the like.
In reality, the characteristics of interest in 'SFC' have more to do with intermolecular interactions in the MP than the name of the fluid. Many of the characteristics that make SFs interesting to chromatographers (e.g., high diffusivity, low viscosity) are also available from some fluids defined as gases or liquids. Unfortunately, the name SFC is somewhat misleading. SFC differs from LC in that the MP is a dense compressed fluid which will dramatically expand if external pressure is removed.
The most widely used supercritical fluids (like carbon dioxide, nitrous oxide, or CHF3) are inorganic and do not produce a response in some GC detectors, like the FID. This combination of characteristics allows some LC-like separations with more GC-like figures of merit, such as high speed, high resolution, and multiple detection options.
Several modern packed column SFC chromatograms may help convey the features that make the technique desirable. In Figure 1.1, the 11 carbamates of EPA Method 531.1 are separated in 9 minutes and directly detected using both a UV and an NPD (Nitrogen–Phosphorus Detector).
The methanol/carbon dioxide (MeOH/CO2) MP flow rate is 2.5 ml min-1, producing near optimum chromatographic efficiency. This is approximately 3.5 times the optimum flow rate in LC (on this column) and illustrates the superior diffusion rate in supercritical fluids.
The standard method uses gradient elution LC2 followed by two postcolumn reactions to yield fluorescent products. Although the separation takes ca. 40 minutes, the column must then be re-equilibrated. The whole process requires ca. 1 hour between injections. A representative chromatogram is shown in Figure 1.2.
Cumulatively, the SFC separation and detection options produce a throughput approximately six times that of the LC standard method, and avoid the complexity of the postcolumn reactions.
An alternative example of the unusual characteristics of SFC is shown in Figure 1.3. The separation in Figure 1.3 was developed to suggest the feasibility of using SFC for screening pesticides not amenable to GC analysis. A 10 ml water sample containing 6–22.5 p.p.b. of 31 carbamate, sulfonylurea, phenylurea, and triazine pesticides was injected into a precolumn mounted in place of an external loop on a six port valve. The water was blown off with helium, and then the precolumn was switched into the flowing stream. The solutes were eluted by a gradient of 1–16% MeOH in CO2, 90–140 bar, from a 1.6 m long LC column packed with 5 µm particles. At 2 ml min-1 of 20% MeOH, the pressure drop was 150 bar. After the column, the flow was split, diverting a fraction to an ECD and an NPD while most passed through the UV diode array detector. The detection limits for some solutes were a few tens of parts per trillion (1/10).
One trend in LC is toward the use of smaller diameter packed columns, requiring less MP. Major reasons are a desire to reduce solvent cost and minimize toxic waste generation. In some locations, it is already more expensive to dispose of solvents than purchase them. Unfortunately, smaller columns require more stringent instrumental design. In general, it is more difficult to achieve the same high efficiencies, and high sensitivity on a small column as on a large column. Packed column SFC offers an attractive alternative. Inert CO2 replaces most of the liquid solvent. Modifiers typically represent 2–20% of the mobile phase. An SFC method on a 4.6 mm column creates the same or less liquid waste as a 2 or even 1 mm LC column. By retaining the larger column format, SFC allows relaxed constraints on extra column effects, while often providing higher capacity, better detection, and reproducibility.
What is a Supercritical Fluid?
It is important to understand that 'Supercritical' is only a defined state. Supercritical fluids are not a separate state of matter (there are only gases, liquids, and solids). To be 'supercritical', a fluid must be above BOTH its critical temperature, Tc, and critical pressure, Pc. The combination of Tc and Pc is known as the 'critical point'. Above its critical point, a fluid cannot be liquified, no matter how high the pressure is raised. Note that the definition only deals with T >Tc and P >Pc. The definition ignores what happens at conditions BELOW the critical point.
There has been a great deal of confusion about transitions from subcritical to supercritical conditions. Such transitions are NOT phase transitions. They are only transitions from one DEFINED state to another. This ambiguity is dealt with in depth in Chapter 3.
Supercritical fluids lack adequate intermolecular interactions which would otherwise condense them to liquids. This low intermolecular energy gives the fluids certain advantageous characteristics compared with normal liquids familiar as mobile phases in LC.
With SFs (and some similar fluids), the pressure can be increased until the molecules are as close to each other as the molecules in a condensed liquid. This molecular...
„Über diesen Titel“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Romtrade Corp.
STERLING HEIGHTS, MI, USA
AbeBooks-Verkäufer/-in seit 17. April 2013
Versandkosten innerhalb von USA
| Artikel | 3 bis 6 Werktage | 5 bis 10 Werktage |
|---|---|---|
| Erster Artikel | EUR 0,00 | EUR 0,00 |
Zahlungsarten
Shop-Beschreibung
We sell textbooks to students at very affordable prices. All books are brand new, satisfaction guaranteed.
Spezialisierung
TextbooksUnternehmensdaten der Verkäuferin bzw. des Verkäufers
Romtrade Corp.
39137 BYERS DR.
STERLING HEIGHTS, MI USA 48310
Verkaufsbedingungen
We guarantee the condition of every book as it's described on the Abebooks web
sites. If you're dissatisfied with your purchase (Incorrect Book/Not as
Described/Damaged) or if the order hasn't arrived, you're eligible for a refund
within 30 days of the estimated delivery date. If you've changed your mind about
a book that you've ordered, please use the Ask bookseller a question link to
contact us and we'll respond within 2 business days. The contact persons name is
Constantin Marandici and the mail id where you can send a mail is
discount_scientific_books@yahoo.com. We can be also contacted at 586-977-9198.
Our address
39137 Byers Dr.
Sterling Heights, MI - 48310
USA
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an Romtrade Corp., Irving, Texas, U.S.A., zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Orders usually ship within 2 business days. Shipping costs are based on books weighing 2.2 LB, or 1 KG. If your book order is heavy or oversized, we may contact you to let you know extra shipping is required. We use USPS, DHL and ARAMEX for shipping.