Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS): 11 (Valid Analytical Measurement)
Sprache: Englisch
Verlag: Royal Society of Chemistry, 2002
- Softcover
- Gebraucht

Anbieter: Reuseabook, Gloucester, GLOS, Vereinigtes KönigreichReuseabook
AbeBooks-Verkäufer/-in seit 24. Juni 2014
Zustand: Gebraucht - Befriedigend
EUR 26,35
Anzahl: 1 verfügbar
In den WarenkorbArtikelbeschreibung des Verkäufers
Dispatched, from the UK, within 48 hours of ordering. This book is in good condition but will show signs of previous ownership. Please expect some creasing to the spine and/or minor damage to the cover.
Bestandsnummer des Verkäufers CHL10803496
- Titel
- Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS): 11 (Valid Analytical Measurement)
- Autor
- Bedson, Peter
- Verlag
- Royal Society of Chemistry
- Erscheinungsjahr
- 2002
- Zustand
- Used; Good
- Einband
- paperback
- Sprache
- Englisch
- ISBN-10
- 0854044183
- ISBN-13
- 9780854044184
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Auszug. © Genehmigter Nachdruck. Alle Rechte vorbehalten.
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS)
By Chris HarringtonThe Royal Society of Chemistry
All rights reserved.
Contents
1 Introduction,
1.1 Advantages and Disadvantages of IDMS, 2,
2 The Principles of IDMS, 3,
3 Critical Stages and Sources of Error, 4,
3.1 Introduction, 4,
3.2 Sample Preparation, 5,
3.3 Selection of the Isotopic Analogue, 6,
3.4 Addition of the Isotopic Analogue, 6,
3.5 Characterisation of the Isotopic Analogue, 7,
3.6 Blank Correction, 8,
3.7 Instrumental Analysis, 8,
3.8 Calibration Procedures, 10,
3.9 Isotopic Interferences, 12,
3.10 Isotopic Discrimination, 14,
3.11 Aspects of Achieving High Accuracy Measurements, 15,
4 The Structured Approach to IDMS analysis, 17,
4.1 The 'Exact signal matching' Method for Organic IDMS, 17,
4.2 The 'Approximate signal matching' method for Inorganic IDMS, 19,
4.3 A Diagrammatic Overview of Inorganic IDMS, 22,
5 Optimised Spiking for Inorganic IDMS Analysis, 30,
5.1 Introduction, 30,
5.2 Key Parameters, 30,
Annex 1: References and Additional Reading, 35,
References, 35,
Additional Organic IDMS Publications, 36,
Additional Inorganic IDMS Publications, 38,
Annex 2: Glossary of Terms and Abbreviations, 41,
Annex 3: Standard IDMS Equations, 46,
CHAPTER 1
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectronometry (IDMS)
1 Introduction
The technique of isotope dilution mass spectrometry (IDMS) was initially developed during the 1950s for elemental analysis. With readily available and user-friendly instrumentation, the number of applications for which elemental IDMS was used developed rapidly. IDMS was extended into the field of organic compounds in the 1970s and the range of applications for which isotopically labelled organic compounds are available continues to grow. IDMS applications range from routine survey work, such as residue analysis of dioxins, to use as a reference technique.
In mass spectrometry, unlike spectrophotometric techniques, there is no fixed relationship between the amount, and concentration, of a particular substance and the instrument response. Sensitivity for a particular compound or ion varies with, for example, time and instrumental tune parameters. These variations are in addition to those caused by, for example, sample introduction and chromatography. To achieve even moderately accurate quantification requires the use of an internal standard. An advantage of mass spectrometry lies in its ability to use isotopically enriched analogues (inorganic mass spectrometry) or isotopically labelled analogues (organic mass spectrometry) as internal standards. Indeed, in some instances IDMS is referred to as 'stable isotope internal standardisation'. Provided the isotopic analogue is added to the sample at the very beginning of the analytical method and it comes into equilibrium with the analyte without losses or isotopic fractionation, it enables exact compensation to be made for errors at all stages of the analysis, from sample digestion/preparation through to the final instrumental measurement.
Initially, IDMS of inorganic analytes was most frequently performed using thermal ionisation mass spectrometry (TIMS). More recently, inductively coupled plasma mass spectrometry (ICP-MS) based IDMS has become more prevalent, because it requires much less sample preparation prior to analysis, and can provide results of the required accuracy and precision. The inorganic sections of this guide are concerned only with the use of ICP-MS for high accuracy IDMS measurements. IDMS of organic analytes can equally well be carried out using the full range of sample inlet systems available, such as GC-MS, LC-MS and the newer technique of capillary zone electrophoresis-mass spectrometry (CZE-MS). Tandem mass spectrometers (MS-MS) can also be used. In some instances, however, the inlet system/mass spectrometer type can have an influence on IDMS analysis. The use of a GC split injector, for example, can cause isotopic fractionation.
The advent of compact and economic instrumentation, such as quadrupole and ion trap mass spectrometers, has led to the increasing use of mass spectrometry in the field of analytical chemistry. As a result, IDMS is playing an increasingly important role in trace analysis. This is also due to its greater accuracy than other calibration methods and its ability to compensate for matrix effects. Notwithstanding this, there are several reasons why, in spite of the unrivalled accuracy and precision possible with the IDMS technique, it is not more widely used. In principle, the method is simple and allows for knowledge or control of all the variables that can lead to error. In practice, achieving accurate results requires careful design of the experiment and considerable attention to detail and is hence quite time consuming. Such factors have led to a slow acceptance of the technique. It has become popular, however, in some analytical fields where the sample matrix makes sufficiently accurate quantification difficult, e.g. clinical analysis. A theoretical discussion on the influence of some instrumental parameters on the precision of IDMS measurements has been published.
1.1 Advantages and Disadvantages of IDMS
The use of IDMS has a number of advantages and disadvantages, which the prospective user should consider.
1.1.1 Advantages
Providing the sample is homogeneous and isotopic equilibrium has been reached, the advantages of IDMS include:
1. It is a definitive method because of its precision, accuracy and provision of definable uncertainty values.
2. Once equilibration of the spike and analyte isotopes has been achieved, the total recovery of the analyte is not required, because the determined value is based on measuring the ratio between the analyte and the isotopic analogue (spike).
3. The accuracy of the method is determined by the precision of this ratio measurement.
4. Analyte transformation (e.g. breakdown) during sample preparation (most applicable to organic analysis) is compensated for by use of the isotopic analogue as internal standard.
5. The methodology is less time consuming and can provide greater accuracy than standard additions.
This guide aims to provide a structured approach to the use of IDMS to achieve high accuracy analytical measurements in both organic and inorganic IDMS. The approach outlined in Sections 4 and 5 has the advantage over normal IDMS of:
1. Negating the need to accurately characterise the isotopic analogue in terms of isotopic abundance and concentration (most applicable to inorganic analysis).
2. Providing a logical framework of understanding, which allows the analyst to identify specific problems, related to their application.
3. Providing a lower uncertainty value.
4. Simplifying the equations used for organic analytes.
1.1.2 Disadvantages of IDMS
1. The cost and availability of suitable isotopic materials.
2. The cost of the mass spectrometry instrumentation required.
3. Training of the analyst is of the utmost importance; otherwise less accurate results are often achieved.
4. Isotopic equilibration needs to be shown to have been achieved.
5. Differences in the physical (e.g. solvation) and chemical properties (e.g. pKa value) between the analyte and the...
„Über diesen Titel“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Reuseabook
Gloucester, GLOS, Vereinigtes Königreich
AbeBooks-Verkäufer/-in seit 24. Juni 2014
Versandkosten von Vereinigtes Königreich nach USA
| Artikel | 7 bis 12 Werktage | 7 bis 12 Werktage |
|---|---|---|
| Erster Artikel | EUR 8,20 | EUR 19,91 |
Zahlungsarten
Shopbeschreibung
Selling used and pre-loved books
Spezialisierung
SecondhandUnternehmensdaten der Verkäuferin bzw. des Verkäufers
Reuseaworld Ltd
Unit A Mill Place 2, 90 Bristol Road
Gloucester, Vereinigtes Königreich GL1 5SQ
Verkaufsbedingungen
Any customer wishing to return a book has 30 days to do so if they are not entirely satisfied.
Upon receipt, a refund of the cost of the book will be issued.
Legal company name : Reuseabook Partnership
Registered and returns address
Unit A
Mill Place 2
Bristol Road,
Gloucester
Gloucestershire
GL1 5SQ
Customer services and general contacts email: abe@reuseabook.com
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an Reuseabook, Gloucester, GLOS, United Kingdom, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Shipping costs are based on books weighing 2.2 LB, or 1 KG. If your book order is heavy or oversized, we may contact you to let you know extra shipping is required.
Unless noted otherwise in the ordering pipeline Reuseabook dispatches all items within two working days of receiving order You will receive notification of any delay or cancellation of your order.