Capillary Electrochromatography (RSC Chromatography Monographs, Volume 7)
Sprache: Englisch
Verlag: Royal Society of Chemistry, 2001
- Hardcover
- Neu

Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes KönigreichRia Christie Collections
AbeBooks-Verkäufer/-in seit 25. März 2015
Zustand: Neu
EUR 97,35
Anzahl: Mehr als 20 verfügbar
In den WarenkorbArtikelbeschreibung vom Verkäufer
In English.
Bestandsnummer des Verkäufers ria9780854045303_new
- Titel
- Capillary Electrochromatography (RSC Chromatography Monographs, Volume 7)
- Verlag
- Royal Society of Chemistry
- Veröffentlichungsjahr
- 2001
- Zustand
- New
- Einband
- Hardcover
- Sprache
- Englisch
- ISBN-10
- 0854045309
- ISBN-13
- 9780854045303
- Artikelgewicht
- 530 Gramm
Capillary electrochromatography (CEC) is a new and exciting hybrid separation technique that seeks to exploit the combined advantages of both capillary electrophoresis (high efficiencies) and HPLC (mobile and stationary phase selectivity). It is a technique with tremendous potential, especially in the pharmaceutical and biomedical fields. This is the first book to be devoted to the topic and presents reviews by the world leaders in the field on the theory and development of the technique and current and potential future applications. Capillary Electrochromatography provides an excellent introduction to the field for graduates and professionals in industry and academia with an interest in separation science.
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Auszug. © Genehmigter Nachdruck. Alle Rechte vorbehalten.
Capillary Electrochromatography
By Keith D. Bartle, Peter MeyersThe Royal Society of Chemistry
All rights reserved.
Contents
Chapter 1 An Introduction to Capillary Electrochromatography Keith D. Bartle, Maria G. Cikalo and Mark M. Robson, 1,
Chapter 2 The Capillary Electrochromatograph Norman W. Smith, 23,
Chapter 3 Supports and Stationary Phases for Capillary Electrochromatography Peter Myers, 33,
Chapter 4 Electroosmosis in Complex Media: Bulk Transport in CEC Vincent T. Remcho and Patrick T. Vallano, 42,
Chapter 5 Capillary Electrochromatography with Open Tubular Columns (OTCEC) Monika M. Dittmann and Gerard P. Rozing, 64,
Chapter 6 Capillary Electrochromatography/Mass Spectrometry G.A. Lord and D.B. Gordon, 87,
Chapter 7 Pharmaceutical Applications of Capillary Electrochromatography Melvin R. Euerby and Nicola C. Gillott, 107,
Chapter 8 Capillary Electrochromatography in Natural Product Research An Dermaux and Pat Sandra, 125,
Subject Index, 146,
CHAPTER 1
An Introduction to Capillary Electrochromatography
KEITH D. BARTLE, MARIA G. CIKALO AND MARK M. ROBSON
1 What is Capillary Electrochromatography?
Capillary electrochromatography (CEC) is a recently developed variant of high-performance liquid chromatography (HPLC) in which the flow of mobile phase is driven through the column by an electric field, a phenomenon known as electroosmosis, rather than by applied pressure. This electroosmotic flow (EOF) is generated by applying a large voltage across the column; positive ions of the added electrolyte accumulate in the electrical double layer of particles of column packing, move towards the cathode and drag the liquid mobile phase with them. As in capillary electrophoresis (CE) and micellar electrokinetic chromatography (MEKC), small diameter (typically 50-100 µm) columns with favourable surface area-to-volume ratio are employed to minimise thermal gradients from ohmic heating, which can have an adverse effect on band widths. CEC differs crucially from CE and MEKC, however, in that the separating principle is partition between the liquid and solid phases (Table 1.1).
Avoiding the use of pressure results in a number of important advantages for CEC over conventional HPLC. Firstly, the pressure-driven flow rate through a packed bed depends directly on the square of the particle diameter and inversely on column length; for practical pressures, generally used particle diameters are seldom less than 3 µm, with column lengths restricted to approximately 25 cm. By contrast the electrically driven flow rate is independent of particle diameter and column length so that, in principle, smaller particles and longer columns can be used. If follows that considerably higher efficiencies can be generated in CEC than in HPLC. A second consequence of employing electrodrive is that the plug-like flow -velocity profile in EOF reduces dispersion of the band of solute as it passes through the column, further increasing column efficiency. The combined effect of reduced particle diameter, increased column length and plug flow leads to CEC efficiencies of typically 200 000 plates per metre, and substantially improved resolution.
Voltages up to 30 kV are applied to generate the electric field usually for solutions of 1–50 mM buffers in aqueous reversed-phase mobile phases, although non-aqueous CEC has also been carried out. The dependence of EOF rate on solvent dielectric constant has been confirmed, but the electrical potential (the zeta potential) of the boundary between the fixed and diffuse layers (the double layer; see pages 43–5 for further discussion) of positive ions at the stationary phase wall (Figure 1.1) is less well understood. The conclusion of an early theoretical study which suggested that flat EOF profiles in a capillary of diameter d would result if d were considerably greater than the double layer thickness, δ, has been confirmed by experiment; for channels between particles, however, the influence of δ is less clear. Current indications are that it should be possible to use monodisperse particles with diameters down to 0.5 µm. Pore sizes of commonly used HPLC particles are too small to give rise to EOF, but larger pore packings show promise. Although CEC has been demonstrated for stationary phases bonded to the walls of open tubes, and in sol–gel derived phases, most work has been carried out on columns packed with HPLC stationary phases; a new generation of packings custom-synthesized for CEC is, however, now beginning to make an impact.
2 History of CEC
Strain first reported the use of the EOF in chromatography; he recognized the difference between electrophoresis and electrochromatography on the one hand, and partitioning of analytes between a mobile and a stationary phase on the other. Electrodrive (electrophoretic mobility and electroosmosis) was used to move the analytes through a separation medium, so that the importance of the EOF was recognized in electrochromatography. Early work in electrical chromatography was either in relatively large diameter columns (>1 mm) or in thin layers, which were used to analyse neutral, basic and acidic molecules by electromigration through a paper matrix.
The separation of polysaccharides using electrodrive through a colloidal membrane is probably the first reported use of EOF to drive a mobile phase through a stationary phase. For thin layers, Kowalczyk quantified the EOF velocity while Hybarger et al. proposed an annular bed system for preparative separations. Cylindrical columns packed with Sephadex were used by a number of groups for protein separation. Gel columns were employed in the separation of high-molecular-weight (>500 kDa) compounds in experiments in which counteracting electrophoretic and hydrodynamic forces were used.
The originators of CEC were, however, the Pretorius group, who reported that if the EOF were used to drive the mobile phase flow, as opposed to the hydrodynamic flow in conventional liquid chromatography, the plate height was reduced. They also pointed out the absence of pressure drop across the column if the EOF were used. Significant progress in CEC began in the 1980s; Jorgenson and Lukacs demonstrated the use of electroosmosis in capillaries and showed the possibilities for low reduced plate heights. Tsuda then showed that CEC was possible in coated open tubular columns and recognized the factors that control the EOF as well as the importance of practical effects, such as bubble formation, in packed columns.
The recent resurgence of CEC dates from the detailed theoretical analysis of Knox and Grant, published in 1987, followed by practical demonstrations by the same group in 1991. Both slurry-packed and draw-packed capillaries were used in a detailed study of factors affecting the EOF. Particle sizes down to 1.5 µm were used, and reduced plate heights near unity were demonstrated in 30–200 µm i.d. columns up to 1 m long. The important observation was made that columns driven electrically show higher efficiencies than the same column with pressure drive (Figure 1.2).
The potential of CEC in the analysis of mixtures relevant to the pharmaceutical industry was realized by Smith and Evans in 1994. The capabilities of CEC were demonstrated in high-resolution chromatograms of drug compounds (e.g. Figure 1.3) on a reversed-phase C18 stationary phase. The same group than went on to show how especially...
„Über diesen Titel“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Ria Christie Collections
Uxbridge, Vereinigtes Königreich
AbeBooks-Verkäufer/-in seit 25. März 2015
Versandkosten von Vereinigtes Königreich nach USA
| Artikel | 6 bis 12 Werktage | 6 bis 12 Werktage |
|---|---|---|
| Erster Artikel | EUR 13,13 | EUR 15,10 |
Zahlungsarten
Shop-Beschreibung
Hello! Ria Christie Collections is an online venture that was initially set up in 2012 to sell books. We do not have a physical high street store. We are professional online booksellers. We only sell brand new books in perfect condition that we source from various suppliers and the publishers. Primarily, our aim is to provide an excellent service to all our customers. We always work as a team to achieve this. Our other objectives are to: 1. Ensure that all our products reach their destination quickly in a safe and secure manner 2. Answer to all our customer queries within 24 hours 3. Ensure that our customers are happy with their purchases 4. Provide all the items at a competitive price 5. Always listen to our customers Ria Christie Collections is not a registered company. It is a Sole Trader venture. Other key information is shown below: Contact Person Name: Rakesh Luchmun (Mr) Storefront Name: Ria Christie Collections Place of Establishment Address: Suite B; ARUN House; ARUN Building Arundel Road Uxbridge UB8 2RR United Kingdom E-Mail Address: riachristie@hotmail.co.uk VAT Number: GB 160 5650 25 We always work hard and aim to comply with all of Abebooks Policies. If you have any issues, please do not hesitate to write to us whether before or after a purchase. We promise to reply to you promptly and, in any case, within 24 hours. Thank you kindly! Yours sincerely Mr Rakesh Luchmun (Founder) and the Ria Christie Collections Team…
Spezialisierung
Educational books, Textbooks, Fiction, Non- fictionUnternehmensdaten der Verkäuferin bzw. des Verkäufers
Ryefield Investments Limited
175 Pield Heath Road
Uxbridge, Vereinigtes Königreich UB8 3NL
Verkaufsbedingungen
All Returns and Refund are as per Abebooks policies.
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an Ria Christie Collections, Uxbridge, United Kingdom, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Orders usually ship within 2 business days. If your book order is heavy or oversized, we may contact you to let you know extra shipping is required. Thank you!