Capillary Electrochromatography
Gordon, D. B.
Verkauft von moluna, Greven, Deutschland
AbeBooks-Verkäufer seit 9. Juli 2020
Neu - Hardcover
Zustand: Neu
Versand von Deutschland nach USA
Anzahl: Mehr als 20 verfügbar
In den Warenkorb legenVerkauft von moluna, Greven, Deutschland
AbeBooks-Verkäufer seit 9. Juli 2020
Zustand: Neu
Anzahl: Mehr als 20 verfügbar
In den Warenkorb legenThis book provides an excellent introduction to the field for graduates and professionals in industry and academia with an interest in separation science.InhaltsverzeichnisAn Introduction to Capillary Electrochromatography The Capil.
Bestandsnummer des Verkäufers 595098209
Capillary electrochromatography (CEC) is a new and exciting hybrid separation technique that seeks to exploit the combined advantages of both capillary electrophoresis (high efficiencies) and HPLC (mobile and stationary phase selectivity). It is a technique with tremendous potential, especially in the pharmaceutical and biomedical fields. This is the first book to be devoted to the topic and presents reviews by the world leaders in the field on the theory and development of the technique and current and potential future applications. Capillary Electrochromatography provides an excellent introduction to the field for graduates and professionals in industry and academia with an interest in separation science.
Chapter 1 An Introduction to Capillary Electrochromatography Keith D. Bartle, Maria G. Cikalo and Mark M. Robson, 1,
Chapter 2 The Capillary Electrochromatograph Norman W. Smith, 23,
Chapter 3 Supports and Stationary Phases for Capillary Electrochromatography Peter Myers, 33,
Chapter 4 Electroosmosis in Complex Media: Bulk Transport in CEC Vincent T. Remcho and Patrick T. Vallano, 42,
Chapter 5 Capillary Electrochromatography with Open Tubular Columns (OTCEC) Monika M. Dittmann and Gerard P. Rozing, 64,
Chapter 6 Capillary Electrochromatography/Mass Spectrometry G.A. Lord and D.B. Gordon, 87,
Chapter 7 Pharmaceutical Applications of Capillary Electrochromatography Melvin R. Euerby and Nicola C. Gillott, 107,
Chapter 8 Capillary Electrochromatography in Natural Product Research An Dermaux and Pat Sandra, 125,
Subject Index, 146,
An Introduction to Capillary Electrochromatography
KEITH D. BARTLE, MARIA G. CIKALO AND MARK M. ROBSON
1 What is Capillary Electrochromatography?
Capillary electrochromatography (CEC) is a recently developed variant of high-performance liquid chromatography (HPLC) in which the flow of mobile phase is driven through the column by an electric field, a phenomenon known as electroosmosis, rather than by applied pressure. This electroosmotic flow (EOF) is generated by applying a large voltage across the column; positive ions of the added electrolyte accumulate in the electrical double layer of particles of column packing, move towards the cathode and drag the liquid mobile phase with them. As in capillary electrophoresis (CE) and micellar electrokinetic chromatography (MEKC), small diameter (typically 50-100 µm) columns with favourable surface area-to-volume ratio are employed to minimise thermal gradients from ohmic heating, which can have an adverse effect on band widths. CEC differs crucially from CE and MEKC, however, in that the separating principle is partition between the liquid and solid phases (Table 1.1).
Avoiding the use of pressure results in a number of important advantages for CEC over conventional HPLC. Firstly, the pressure-driven flow rate through a packed bed depends directly on the square of the particle diameter and inversely on column length; for practical pressures, generally used particle diameters are seldom less than 3 µm, with column lengths restricted to approximately 25 cm. By contrast the electrically driven flow rate is independent of particle diameter and column length so that, in principle, smaller particles and longer columns can be used. If follows that considerably higher efficiencies can be generated in CEC than in HPLC. A second consequence of employing electrodrive is that the plug-like flow -velocity profile in EOF reduces dispersion of the band of solute as it passes through the column, further increasing column efficiency. The combined effect of reduced particle diameter, increased column length and plug flow leads to CEC efficiencies of typically 200 000 plates per metre, and substantially improved resolution.
Voltages up to 30 kV are applied to generate the electric field usually for solutions of 1–50 mM buffers in aqueous reversed-phase mobile phases, although non-aqueous CEC has also been carried out. The dependence of EOF rate on solvent dielectric constant has been confirmed, but the electrical potential (the zeta potential) of the boundary between the fixed and diffuse layers (the double layer; see pages 43–5 for further discussion) of positive ions at the stationary phase wall (Figure 1.1) is less well understood. The conclusion of an early theoretical study which suggested that flat EOF profiles in a capillary of diameter d would result if d were considerably greater than the double layer thickness, δ, has been confirmed by experiment; for channels between particles, however, the influence of δ is less clear. Current indications are that it should be possible to use monodisperse particles with diameters down to 0.5 µm. Pore sizes of commonly used HPLC particles are too small to give rise to EOF, but larger pore packings show promise. Although CEC has been demonstrated for stationary phases bonded to the walls of open tubes, and in sol–gel derived phases, most work has been carried out on columns packed with HPLC stationary phases; a new generation of packings custom-synthesized for CEC is, however, now beginning to make an impact.
2 History of CEC
Strain first reported the use of the EOF in chromatography; he recognized the difference between electrophoresis and electrochromatography on the one hand, and partitioning of analytes between a mobile and a stationary phase on the other. Electrodrive (electrophoretic mobility and electroosmosis) was used to move the analytes through a separation medium, so that the importance of the EOF was recognized in electrochromatography. Early work in electrical chromatography was either in relatively large diameter columns (>1 mm) or in thin layers, which were used to analyse neutral, basic and acidic molecules by electromigration through a paper matrix.
The separation of polysaccharides using electrodrive through a colloidal membrane is probably the first reported use of EOF to drive a mobile phase through a stationary phase. For thin layers, Kowalczyk quantified the EOF velocity while Hybarger et al. proposed an annular bed system for preparative separations. Cylindrical columns packed with Sephadex were used by a number of groups for protein separation. Gel columns were employed in the separation of high-molecular-weight (>500 kDa) compounds in experiments in which counteracting electrophoretic and hydrodynamic forces were used.
The originators of CEC were, however, the Pretorius group, who reported that if the EOF were used to drive the mobile phase flow, as opposed to the hydrodynamic flow in conventional liquid chromatography, the plate height was reduced. They also pointed out the absence of pressure drop across the column if the EOF were used. Significant progress in CEC began in the 1980s; Jorgenson and Lukacs demonstrated the use of electroosmosis in capillaries and showed the possibilities for low reduced plate heights. Tsuda then showed that CEC was possible in coated open tubular columns and recognized the factors that control the EOF as well as the importance of practical effects, such as bubble formation, in packed columns.
The recent resurgence of CEC dates from the detailed theoretical analysis of Knox and Grant, published in 1987, followed by practical demonstrations by the same group in 1991. Both slurry-packed and draw-packed capillaries were used in a detailed study of factors affecting the EOF. Particle sizes down to 1.5 µm were used, and reduced plate heights near unity were demonstrated in 30–200 µm i.d. columns up to 1 m long. The important observation was made that columns driven electrically show higher efficiencies than the same column with pressure drive (Figure 1.2).
The potential of CEC in the analysis of mixtures relevant to the pharmaceutical industry was realized by Smith and Evans in 1994. The capabilities of CEC were demonstrated in high-resolution chromatograms of drug compounds (e.g. Figure 1.3) on a reversed-phase C18 stationary phase. The same group than went on to show how especially...
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Allgemeine Geschäftsbedingungen und Kundeninformationen/Datenschutzerklärung
I. Allgemeine Geschäftsbedingungen
§ 1 Grundlegende Bestimmungen
(1) Die nachstehenden Geschäftsbedingungen gelten für Verträge, die Sie mit uns als Anbieter (Moluna GmbH) über die Internetplattformen AbeBooks schließen. Soweit nicht anders vereinbart, wird der Einbeziehung gegebenenfalls von Ihnen verwendeter eigener Bedingungen widersprochen.
(2) Verbraucher im Sinne der nachstehenden Regelungen ist jede natürliche Pe...
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an moluna, Greven, Germany, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
II. Kundeninformationen
Moluna GmbH
Engberdingdamm 27
48268 Greven
Deutschland
Telefon: 02571/5698933
E-Mail: abe@moluna.de
Wir sind nicht bereit und nicht verpflichtet, an Streitbeilegungsverfahren vor Verbraucherschlichtungsstellen teilzunehmen.
Die technischen Schritte zum Vertragsschluss, der Vertragsschluss selbst und die Korrekturmöglichkeiten erfolgen nach Maßgabe der Regelungen "Zustandekommen des Vertrages" unserer Allgemeinen Geschäftsbedingungen (Teil I.).
3.1. Vertragssprache ist deutsch .
3.2. Der vollständige Vertragstext wird von uns nicht gespeichert. Vor Absenden der Bestellung können die Vertragsdaten über die Druckfunktion des Browsers ausgedruckt oder elektronisch gesichert werden. Nach Zugang der Bestellung bei uns werden die Bestelldaten, die gesetzlich vorgeschriebenen Informationen bei Fernabsatzverträgen und die Allgemeinen Geschäftsbedingungen nochmals per E-Mail an Sie übersandt.
Die wesentlichen Merkmale der Ware und/oder Dienstleistung finden sich im jeweiligen Angebot.
5.1. Die in den jeweiligen Angeboten angeführten Preise sowie die Versandkosten stellen Gesamtpreise dar. Sie beinhalten alle Preisbestandteile einschließlich aller anfallenden Steuern.
5.2. Die anfallenden Versandkosten sind nicht im Kaufpreis enthalten. Sie sind über eine entsprechend bezeichnete Schaltfläche auf unserer Internetpräsenz oder im jeweiligen Angebot aufrufbar, werden im Laufe des Bestellvorganges gesondert ausgewiesen und sind von Ihnen zusätzlich zu tragen, soweit nicht die versandkostenfreie Lieferung zugesagt ist.
5.3. Die Ihnen zur Verfügung stehenden Zahlungsarten sind unter einer entsprechend bezeichneten Schaltfläche auf unserer Internetpräsenz oder im jeweiligen Angebot ausgewiesen.
5.4. Soweit bei den einzelnen Zahlungsarten nicht anders angegeben, sind die Zahlungsansprüche aus dem geschlossenen Vertrag sofort zur Zahlung fällig.
6.1. Die Lieferbedingungen, der Liefertermin sowie gegebenenfalls bestehende Lieferbeschränkungen finden sich unter einer entsprechend bezeichneten Schaltfläche auf unserer Internetpräsenz oder im jeweiligen Angebot.
Soweit im jeweiligen Angebot oder unter der entsprechend bezeichneten Schaltfläche keine andere Frist angegeben ist, erfolgt die Lieferung der Ware innerhalb von 3-5 Tagen nach Vertragsschluss (bei vereinbarter Vorauszahlung jedoch erst nach dem Zeitpunkt Ihrer Zahlungsanweisung).
6.2. Soweit Sie Verbraucher sind ist gesetzlich geregelt, dass die Gefahr des zufälligen Untergangs und der zufälligen Verschlechterung der verkauften Sache während der Versendung erst mit der Übergabe der Ware an Sie übergeht, unabhängig davon, ob die Versendung versichert oder unversichert erfolgt. Dies gilt nicht, wenn Sie eigenständig ein nicht vom Unternehmer benanntes Transportunternehmen oder eine sonst zur Ausführung der Versendung bestimmte Person beauftragt haben.
Sind Sie Unternehmer, erfolgt die Lieferung und Versendung auf Ihre Gefahr.
Die Mängelhaftung richtet sich nach der Regelung "Gewährleistung" in unseren Allgemeinen Geschäftsbedingungen (Teil I).
letzte Aktualisierung: 23.10.2019
| Bestellmenge | 26 bis 60 Werktage | 26 bis 60 Werktage |
|---|---|---|
| Erster Artikel | EUR 48.99 | EUR 48.99 |
Die Versandzeiten werden von den Verkäuferinnen und Verkäufern festgelegt. Sie variieren je nach Versanddienstleister und Standort. Sendungen, die den Zoll passieren, können Verzögerungen unterliegen. Eventuell anfallende Abgaben oder Gebühren sind von der Käuferin bzw. dem Käufer zu tragen. Die Verkäuferin bzw. der Verkäufer kann Sie bezüglich zusätzlicher Versandkosten kontaktieren, um einen möglichen Anstieg der Versandkosten für Ihre Artikel auszugleichen.