Transmission Line Integrated Protection and Auto-Reclosure Scheme: Transmission Line Protection and Auto-Reclosure Scheme - Softcover

Gouda, Ossama; Khalifa, Dina

 
9783847311898: Transmission Line Integrated Protection and Auto-Reclosure Scheme: Transmission Line Protection and Auto-Reclosure Scheme

Inhaltsangabe

This book presents a new transmission line protection scheme using voltage transient waveforms and fundamental voltage and current signals. The scheme integrates the high frequency transient protection algorithms with the synchronized sampling fault location algorithms to produce high speed fault detection and accurate location to the fault. The algorithms were enhanced by a new fault classification technique based on wavelet singular entropy and neural networks to classify different fault types and detect arcing activity within the faultIn order to reach better reliability and stability to the transmission network, transient adaptive single pole auto reclosing scheme (SPAR) was introduced. In the case of transient faults, the arcing extinction time can be accurately determined and in the case of a permanent fault, breaker re-closure can be avoided.

Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.

Reseña del editor

This book presents a new transmission line protection scheme using voltage transient waveforms and fundamental voltage and current signals. The scheme integrates the high frequency transient protection algorithms with the synchronized sampling fault location algorithms to produce high speed fault detection and accurate location to the fault. The algorithms were enhanced by a new fault classification technique based on wavelet singular entropy and neural networks to classify different fault types and detect arcing activity within the faultIn order to reach better reliability and stability to the transmission network, transient adaptive single pole auto reclosing scheme (SPAR) was introduced. In the case of transient faults, the arcing extinction time can be accurately determined and in the case of a permanent fault, breaker re-closure can be avoided.

Biografía del autor

Prof.Dr.Ossama Gouda is the professor of Electrical Engineering in the Electrical Power ,Cairo University since 1993.He is a consultant of several Egyptian firms.He conducted aboout 110 papers and six books in the field of Electrical power and High Vltage Eineering. He conducted about 150 short courses in his field