    A simple, fast and precise (RP-HPLC) reversed phase high performance liquid chromatographic method is developed for the determination of Nitazoxanide. The linearity of Nitazoxanide was found in the range of 50 to 150 μg/ml. The recovery was calculated by standard addition method. The average recovery was found to be 99.81% for our product. The proposed method was found to be accurate, precise and rapid for determination of Nitazoxanide.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
A simple, fast and precise (RP-HPLC) reversed phase high performance liquid chromatographic method is developed for the determination of Nitazoxanide. The linearity of Nitazoxanide was found in the range of 50 to 150 μg/ml. The recovery was calculated by standard addition method. The average recovery was found to be 99.81% for our product. The proposed method was found to be accurate, precise and rapid for determination of Nitazoxanide.
Mr.Pankaj Working as a Principal in Punjab college of pharmacy,vpo saian wala,ferozepur,Punjab.He has Published Research Papers different National and International Journals.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In. Artikel-Nr. ria9783844324419_new
Anzahl: Mehr als 20 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. RP-HPLC Method Development in Nitazoxanide | RP-HPLC Method Development & Validation for determination of percentage content in Nitazoxanide | Pankaj Sachdeva (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783844324419 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Artikel-Nr. 106361242
Anzahl: 5 verfügbar