The grid codes require taking into account the reactive power of the wind farm/park in order to contribute to the network stability, thus operating the wind farm as active compensator device. This book gives a comparative study of stabilizing wind farms using flexible ac transmission systems (FACTS) units like the (Static Synchronous Compensator) STATCOM and the variable speed wind turbines like the Doubly Fed Induction Generators (DFIGs) during wind speed change and grid fault. Both systems can provide reactive power to the wind farms during dynamic and transient conditions. Simulation analyses were carried out in laboratory standard simulation software called power system computer aided design/electromagnetic transient including DC (PSCAD/EMTDC). The simulated results show that the wind farms could be effectively stabilized with both systems. However, the cost is reduced with the DFIGs system because, apart from generating electric power during steady state,it can also provide reactive power through its frequency converters to stabilize the wind farms without the need of an external reactive power compensation units like the STACOM.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
The grid codes require taking into account the reactive power of the wind farm/park in order to contribute to the network stability, thus operating the wind farm as active compensator device. This book gives a comparative study of stabilizing wind farms using flexible ac transmission systems (FACTS) units like the (Static Synchronous Compensator) STATCOM and the variable speed wind turbines like the Doubly Fed Induction Generators (DFIGs) during wind speed change and grid fault. Both systems can provide reactive power to the wind farms during dynamic and transient conditions. Simulation analyses were carried out in laboratory standard simulation software called power system computer aided design/electromagnetic transient including DC (PSCAD/EMTDC). The simulated results show that the wind farms could be effectively stabilized with both systems. However, the cost is reduced with the DFIGs system because, apart from generating electric power during steady state,it can also provide reactive power through its frequency converters to stabilize the wind farms without the need of an external reactive power compensation units like the STACOM.
Okedu Eloghene Kenneth-Discipline: Electrical and Electronic Engineering. Research interests are power system stability, wind energy conversion, dynamic and transient analyses of wind parks and augmentation/integration of renewable energy to power system.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Wind Energy for Power Generation | Dynamic and Transient Analyses of Wind Parks Equipped with FACTS Devices and Variable Speed Wind Turbines Control Strategies | Kenneth Eloghene Okedu | Taschenbuch | 172 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844323375 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Artikel-Nr. 107061517
Anzahl: 5 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. Neuware -The grid codes require taking into account the reactive power of the wind farm/park in order to contribute to the network stability, thus operating the wind farm as active compensator device. This book gives a comparative study of stabilizing wind farms using flexible ac transmission systems (FACTS) units like the (Static Synchronous Compensator) STATCOM and the variable speed wind turbines like the Doubly Fed Induction Generators (DFIGs) during wind speed change and grid fault. Both systems can provide reactive power to the wind farms during dynamic and transient conditions. Simulation analyses were carried out in laboratory standard simulation software called power system computer aided design/electromagnetic transient including DC (PSCAD/EMTDC). The simulated results show that the wind farms could be effectively stabilized with both systems. However, the cost is reduced with the DFIGs system because, apart from generating electric power during steady state,it can also provide reactive power through its frequency converters to stabilize the wind farms without the need of an external reactive power compensation units like the STACOM.Books on Demand GmbH, Überseering 33, 22297 Hamburg 172 pp. Englisch. Artikel-Nr. 9783844323375
Anzahl: 2 verfügbar