Verwandte Artikel zu Power Factor Improvement of Cascaded Buck- Boost Converter

Power Factor Improvement of Cascaded Buck- Boost Converter - Softcover

 
9783330069497: Power Factor Improvement of Cascaded Buck- Boost Converter

Inhaltsangabe

The conventional ac-dc conversion utilizes full wave bridge rectifier, and a capacitor as output filter. The ripple at the output of the capacitor is removed by the voltage regulator (dc-dc converter). Lot of harmonic currents at the load are undesirable because they produce distortion such as electromagnetic field interference (EMI), noise, etc. For distortion less output, line voltage and line current must have same phase. If line voltage and line current are not in same phase, then extra circuits must be adding to the converter to make the circuit in same phase. Line voltage and line current in same phase is called unity power factor, and the technique is called unity power factor correction. For ideal sine wave generator, its higher order harmonic currents do not contribute any power to the load but increase the root mean square (rms) current in the distribution line. As a result, it produces extra losses, which is undesirable. If the boost converter has unity power factor, then maximum active power is transferred to its load. As a result, ideal utility power factor is achieved.

Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.

Gratis für den Versand innerhalb von/der Deutschland

Versandziele, Kosten & Dauer

Suchergebnisse für Power Factor Improvement of Cascaded Buck- Boost Converter

Foto des Verkäufers

Amit Kumar Pandey
ISBN 10: 333006949X ISBN 13: 9783330069497
Neu Taschenbuch

Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland

Verkäuferbewertung 5 von 5 Sternen 5 Sterne, Erfahren Sie mehr über Verkäufer-Bewertungen

Taschenbuch. Zustand: Neu. Neuware -The conventional ac-dc conversion utilizes full wave bridge rectifier, and a capacitor as output filter. The ripple at the output of the capacitor is removed by the voltage regulator (dc-dc converter). Lot of harmonic currents at the load are undesirable because they produce distortion such as electromagnetic field interference (EMI), noise, etc. For distortion less output, line voltage and line current must have same phase. If line voltage and line current are not in same phase, then extra circuits must be adding to the converter to make the circuit in same phase. Line voltage and line current in same phase is called unity power factor, and the technique is called unity power factor correction. For ideal sine wave generator, its higher order harmonic currents do not contribute any power to the load but increase the root mean square (rms) current in the distribution line. As a result, it produces extra losses, which is undesirable. If the boost converter has unity power factor, then maximum active power is transferred to its load. As a result, ideal utility power factor is achieved.Books on Demand GmbH, Überseering 33, 22297 Hamburg 56 pp. Englisch. Artikel-Nr. 9783330069497

Verkäufer kontaktieren

Neu kaufen

EUR 39,90
Währung umrechnen
Versand: Gratis
Innerhalb Deutschlands
Versandziele, Kosten & Dauer

Anzahl: 2 verfügbar

In den Warenkorb

Beispielbild für diese ISBN

Pandey, Dr. Amit Kumar
ISBN 10: 333006949X ISBN 13: 9783330069497
Neu Paperback

Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich

Verkäuferbewertung 5 von 5 Sternen 5 Sterne, Erfahren Sie mehr über Verkäufer-Bewertungen

Paperback. Zustand: Brand New. 56 pages. 8.66x5.91x0.13 inches. In Stock. Artikel-Nr. 333006949X

Verkäufer kontaktieren

Neu kaufen

EUR 69,63
Währung umrechnen
Versand: EUR 11,45
Von Vereinigtes Königreich nach Deutschland
Versandziele, Kosten & Dauer

Anzahl: 1 verfügbar

In den Warenkorb