Excerpt from Design and Cost Estimate of a 25, 000 K. V. A. Generating System<br/><br/>All concrete work is of l-2%b5 mix. Foundations for main walls, main units to chimneys are six feet in depth (to bed-rock). The main walls are 20 in thick ness and of a total volume of 420 cu. Yds. The chimney foundations are of an average diam. Of 16' and of a total volume of 90 cu. Yds. The foundations for the turbo-generators are as shown in the plan and of a total volume of 155 cu. Yds.; for the two rotary converters in the included substation, a total volume of 20 cu. Yds. The floors of boiler room, and basement, tur bine-room, and switch house are of a total volume of.