Verwandte Artikel zu Physical review Volume 5

Physical review Volume 5 - Softcover

 
9781236199775: Physical review Volume 5

Zu dieser ISBN ist aktuell kein Angebot verfügbar.

Inhaltsangabe

This historic book may have numerous typos and missing text. Purchasers can download a free scanned copy of the original book (without typos) from the publisher. Not indexed. Not illustrated. 1915 Excerpt: ... a different value for each value of the ballistic throw over the entire scale. In a supposedly high grade instrument differences as high as 20 per cent. in the constant have been found. In a given deflection or ballistic instrument the best condition for proportionality of deflections and throws with steady and instantaneous currents, respectively, obtains when the axis of the coil is coincident with the axis of symmetry of the magnet. To keep these axes coincident when the coil assumes different angular positions it is necessary that the upper suspension terminals be short--so as to avoid the possibility of bent terminals--and parallel to the fiber, and that the lower suspension be so constructed as to exert no lateral force upon the coil. This last named condition is closely complied with if the torque is made small, and if there is no deformation in the regular turns of the spiral. The adjustment of the position of the coil in the field when once carefully made should be easily reproducible when disturbed. A very convenient method is to provide the galvanometer with an adjustable leveling device such as a spirit level, or a plumb-line with a movable indicator. The level or indicator may be set permanently when the desired adjustment of the coil is accomplished. 1 Abstract of a paper presented at the Philadelphia meeting of the Physical Society, December 31, 1914. By Paul E. Klopsteg. The bifilar action of a twisted strip upper suspension has been found negligible in its effect upon galvanometer sensitivity. The effect of difference in torques for twisting and untwisting of the lower suspension (1.5-mil strip, 7 turns) has been found comparable with experimental error. Physical Laboratory, University Of Minnesota. Preliminary Note On A Mercury Vapor Tube...

Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.

Reseña del editor

This historic book may have numerous typos and missing text. Purchasers can download a free scanned copy of the original book (without typos) from the publisher. Not indexed. Not illustrated. 1915 Excerpt: ... a different value for each value of the ballistic throw over the entire scale. In a supposedly high grade instrument differences as high as 20 per cent. in the constant have been found. In a given deflection or ballistic instrument the best condition for proportionality of deflections and throws with steady and instantaneous currents, respectively, obtains when the axis of the coil is coincident with the axis of symmetry of the magnet. To keep these axes coincident when the coil assumes different angular positions it is necessary that the upper suspension terminals be short--so as to avoid the possibility of bent terminals--and parallel to the fiber, and that the lower suspension be so constructed as to exert no lateral force upon the coil. This last named condition is closely complied with if the torque is made small, and if there is no deformation in the regular turns of the spiral. The adjustment of the position of the coil in the field when once carefully made should be easily reproducible when disturbed. A very convenient method is to provide the galvanometer with an adjustable leveling device such as a spirit level, or a plumb-line with a movable indicator. The level or indicator may be set permanently when the desired adjustment of the coil is accomplished. 1 Abstract of a paper presented at the Philadelphia meeting of the Physical Society, December 31, 1914. By Paul E. Klopsteg. The bifilar action of a twisted strip upper suspension has been found negligible in its effect upon galvanometer sensitivity. The effect of difference in torques for twisting and untwisting of the lower suspension (1.5-mil strip, 7 turns) has been found comparable with experimental error. Physical Laboratory, University Of Minnesota. Preliminary Note On A Mercury Vapor Tube...

„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.

(Keine Angebote verfügbar)

Buch Finden:



Kaufgesuch aufgeben

Sie kennen Autor und Titel des Buches und finden es trotzdem nicht auf ZVAB? Dann geben Sie einen Suchauftrag auf und wir informieren Sie automatisch, sobald das Buch verfügbar ist!

Kaufgesuch aufgeben