The symposium from which this book originates represents a sig nificant watershed in the field of intraoperative neural monitoring, since the participants concluded that electrophysiologic monitoring techniques should be considered a "standard of care" for surgical pro cedures that place the central nervous system (CNS) at risk for injury. Specifically, it was agreed that the somatosensory-evoked potential (SEP) is a remarkably reliable and sensitive indicator of several aspects of CNS function, and should be routinely employed as an intraopera tive monitor during many neurosurgical and orthopedic procedures. The significance of this conclusion cannot be overstated, for at the time of this writing, intraoperative monitoring methods based on evoked-potential analyses are still considered experimental and are not in routine use. The reasons for this are not clear, given the accu mulation of literature and expertise on this subject over the past five years. Granted, the cost of electrophysiological monitoring equip ment is high, but only initially. The benefits of injury prevention far outweigh these costs, from both medical and economic viewpoints. It is our sincere hope and goal that the medical community be made aware of the value of intraoperative neural monitoring.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: books4less (Versandantiquariat Petra Gros GmbH & Co. KG), Welling, Deutschland
gebundene Ausgabe. Zustand: Gut. 322 Seiten Der Erhaltungszustand des hier angebotenen Werks ist trotz seiner Bibliotheksnutzung sehr sauber. Es befindet sich neben dem Rückenschild lediglich ein Bibliotheksstempel im Buch; ordnungsgemäß entwidmet. In ENGLISCHER Sprache. Sprache: Englisch Gewicht in Gramm: 720. Artikel-Nr. 1813950
Anzahl: 1 verfügbar
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In. Artikel-Nr. ria9780896031890_new
Anzahl: Mehr als 20 verfügbar
Anbieter: moluna, Greven, Deutschland
Gebunden. Zustand: New. Artikel-Nr. 458446031
Anzahl: Mehr als 20 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Buch. Zustand: Neu. Neuware - The symposium from which this book originates represents a sig nificant watershed in the field of intraoperative neural monitoring, since the participants concluded that electrophysiologic monitoring techniques should be considered a 'standard of care' for surgical pro cedures that place the central nervous system (CNS) at risk for injury. Specifically, it was agreed that the somatosensory-evoked potential (SEP) is a remarkably reliable and sensitive indicator of several aspects of CNS function, and should be routinely employed as an intraopera tive monitor during many neurosurgical and orthopedic procedures. The significance of this conclusion cannot be overstated, for at the time of this writing, intraoperative monitoring methods based on evoked-potential analyses are still considered experimental and are not in routine use. The reasons for this are not clear, given the accu mulation of literature and expertise on this subject over the past five years. Granted, the cost of electrophysiological monitoring equip ment is high, but only initially. The benefits of injury prevention far outweigh these costs, from both medical and economic viewpoints. It is our sincere hope and goal that the medical community be made aware of the value of intraoperative neural monitoring. Artikel-Nr. 9780896031890
Anzahl: 2 verfügbar