Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.
The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.
The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious. The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
EUR 6,39 für den Versand von Vereinigtes Königreich nach Deutschland
Versandziele, Kosten & DauerEUR 10,25 für den Versand von Vereinigtes Königreich nach Deutschland
Versandziele, Kosten & DauerAnbieter: Anybook.com, Lincoln, Vereinigtes Königreich
Zustand: Fair. This is an ex-library book and may have the usual library/used-book markings inside.This book has soft covers. In fair condition, suitable as a study copy. Please note the Image in this listing is a stock photo and may not match the covers of the actual item,350grams, ISBN:9780727725264. Artikel-Nr. 8717816
Anzahl: 1 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. pp. 56. Artikel-Nr. 7423420
Anzahl: 1 verfügbar
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In. Artikel-Nr. ria9780727725264_new
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Buch. Zustand: Neu. Neuware - Masonry walls are not isotropic, they have less strength in bending in the vertical direction than in the horizontal.The design of 2-way spanning masonry panels under lateral loads is complicated, the design tables in this book present a practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. Artikel-Nr. 9780727725264
Anzahl: 1 verfügbar
Anbieter: PBShop.store UK, Fairford, GLOS, Vereinigtes Königreich
PAP. Zustand: New. New Book. Shipped from UK. Established seller since 2000. Artikel-Nr. FW-9780727725264
Anzahl: 1 verfügbar
Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich
Paperback. Zustand: Brand New. 1996 edition. 56 pages. 11.42x7.95x0.31 inches. In Stock. Artikel-Nr. __0727725262
Anzahl: 1 verfügbar
Anbieter: Kennys Bookstore, Olney, MD, USA
Zustand: New. Artikel-Nr. V9780727725264
Anzahl: 1 verfügbar